This section includes all labor, materials, tools, equipment scaffolding
and services required to finish and install all basketball backstops:
Finish and install ceiling suspended, rear fold, rear brace,
backstops with backboards, goals and nets.
Clean up and disposal of debris as a result of this work.
Work not included:
All electrical power, conduit, wiring, junction boxes, key switches
and plugs which shall be installed by electrical contractor.
Finished coat of paint (if necessary).
1.02 SUBMITTALS
Shop Drawings: Contractor shall submit to the architect complete shop
drawings and as built drawings. Drawings shall show method of anchoring,
support, mounting locations, etc. Templates for all embedded bolt anchorages,
sleeves, etc. Six (6) copies of each drawing or diagram shall be submitted.
1.03 WARRANTY
Furnish three (3) copies of a written guarantee of all labor,
equipment and materials for a period of all five (5) years from the date of
substantial completion of the building.
PART 2 – PRODUCTS
2.01 MANUFACTURERS
Acceptable manufacturers: Subject to compliance with requirements,
with minor variations as accepted by manufacturer due to manufacturing
differences, provide products by one of the following:
ADP LEMCO INC.
5970 W Dannon Way West Jordan Ut. 84088-6203
Phone toll free: 800-575-3626, Email: sales@adplemco.com
2.02 MATERIALS FOR MODEL RITE-WALL SERIES 200 SAFETY WALL PADS
Model Rite-Wall Series 200 “Urethane” Pads will be
manufactured from flexible urethane foam 90 ILD (Indentation Load
Deflection) laminated to a 7/16” thick OSB (Oriented Strand Board)
substrate and covered with polyester reinforced heavy-duty vinyl.
A 1” vinyl covered installation strip is provided at the top and
bottom for easy installation (no strip construction optional).
The vinyl fabric is 14 oz. Per square yard non-tear laminated
polyester. All vinyl is fortified with an infection combating
fungicide and anti microbial. The vinyl fabric meets California
State Fire Marshall’s (no. CPA1-84 Standard). Industry standard
size is 2’-0” x 6’-0”. Custom size pads can be produced to fit
specific wall sizes, protruding corners, columns etc. Various
colors are available.
PART 3 – EXECUTION
3.01 INSTALLATION
Shall be completed by an installer who is experienced in installing basketball backstops.
The manufacturer shall approve installer.
Installation shall adhere to manufacturers printed instructions and accepted shop drawings.