This section includes all labor, materials, tools, equipment scaffolding
and services required to finish and install all basketball backstops:
Finish and install ceiling suspended, rear fold, rear brace,
backstops with backboards, goals and nets.
Clean up and disposal of debris as a result of this work.
Work not included:
All electrical power, conduit, wiring, junction boxes, key switches
and plugs which shall be installed by electrical contractor.
Finished coat of paint (if necessary).
1.02 SUBMITTALS
Shop Drawings: Contractor shall submit to the architect complete shop
drawings and as built drawings. Drawings shall show method of anchoring,
support, mounting locations, etc. Templates for all embedded bolt anchorages,
sleeves, etc. Six (6) copies of each drawing or diagram shall be submitted.
1.03 WARRANTY
Furnish three (3) copies of a written guarantee of all labor,
equipment and materials for a period of all five (5) years from the date of
substantial completion of the building.
PART 2 – PRODUCTS
2.01 MANUFACTURERS
Acceptable manufacturers: Subject to compliance with requirements,
with minor variations as accepted by manufacturer due to manufacturing
differences, provide products by one of the following:
ADP LEMCO INC.
5970 W Dannon Way West Jordan Ut. 84088-6203
Phone toll free: 800-575-3626, Email: sales@adplemco.com
2.02 MATERIALS FOR MODEL NO 7000 TRAINING CAGE (BASEBALL, SOCCER, FOOTBALL)
The conventional unit will be supported by die formed fittings(rated
at 2000 lbs per connection). Die formed fittings are spaced at 10'-0
o.c. maximum and shall conform to building structure support members
(provided by others). Each rotating mechanism is connected to the
fittings with two (2) ½" all thread rods which supports the 2 3/8"
o.d. drive pipe. The training cage frame shall be manufactured with
1 5/8" o.d. pipe. The unit is raised, lowered and supported by 3/16"
steel aircraft cables (2000 lbs. break strength each) at 10-'0 o.c.
maximum and terminated at the drive pipe for each cable. The hoist
mechanism will be comprised of a 3/4 h.p. single phase electric motor,
120 vac, 60 cycle, The mechanism includes automatic thermal overload
protection and instant reverse capabilities. This hoist mechanism
will contain integral rotary counting limit switches to automatically
stop the cage in a stored or down position. A direct connection
of an electric motor to the c-faced gear reducer (60:1 ratio)
eliminates the need for any pulleys and v-belts to power the drive
pipe. The gear reducer shall include double output shafts and an
oil level window to insure years of extended use. The change of
direction shall be performed by a reversing contactor containing
two (2) solinoids with equal or greater rating than the electric
motor.
PART 3 – EXECUTION
3.01 INSTALLATION
Shall be completed by an installer who is experienced in installing basketball backstops.
The manufacturer shall approve installer.
Installation shall adhere to manufacturers printed instructions and accepted shop drawings.